INTIAL/ROUTINE LOAD TEST
Our Services

VERTICAL LOAD TEST

VERTICAL LOAD TEST

Two types of Pile load tests are generally conducted at the site, initial and routine, to determine load-carrying capacity and get an idea of the suitability of the piling system. The mode of loading can be vertical, lateral and pull-out depending upon the site requirement. With the help of a routine pile load test, we can check safe load capacity as determined from static analysis. In the case of the initial pile load test procedure, the applied load reaches 2.5 times the safe estimated load, and the routine pile load test, the applied load, reaches 1.5 times the safe estimated load.